FerrAlert™ Halo II Plus guards at the entrance into the MRI exam room, providing the most precise and reliable detection of medium to large ferromagnetic threats. FerrAlert™ Halo II Plus provides significant assistance in the prevention of serious injury to patients and staff or equipment damage. FerrAlert™ detectors are recognized to be the most accurate ferromagnetic detectors for MRI due to their exclusive location-specificity feature. FerrAlert™ detectors have been independently tested to be the most sensitive in real-world MRI environments due to its unique and patented sensor technology.
Easily Understood Status Indicators:
The GREEN LED HALO array illuminated around the MRI entrance indicates that the detector is scanning and there are no ferromagnetic threats detected.
A YELLOW beacon light indicates that a threat is approaching the portal.
The RED LED HALO array flashes the entire portal, indicating a major threat such as a ventilator or oxygen cylinder is approaching the portal.
The greater the threat, the further away the warning is activated. Ferrous objects not approaching the entrance to Zone IV do not trigger an audible warning. A ferromagnetic object is not a threat until it tries to enter the magnet room.
FerrAlert™HALO II shown alarming and locating a ferromagnetic object being carried by patient about to enter the Magnet Room. Location LEDs pinpoint a potential threat.
FerrAlert™ Additional Features: | Specifications: |
Most Flexible Installation for All Facility Architectural Layouts Mounts unobtrusively with both in-swing and out-swing doors | Dimensions: Height 83” (211 cm), Depth 2.25” (5.7 cm) |
Alarm Lights NOT Blocked by an Outward Swinging Door | Adjustable Width: 44” (112 cm) to 54” (137 cm) Inside; 49” (124 cm) to 59” (150 cm) Outside; other width ranges are available |
Continuous Magnetic Disturbance Monitoring provides instant feedback via highly visible bar graphs | Complies with ES60601-1-8 International Standards for Medical Device Alarms |
Safe Passive Detection NO electromagnetic radiation, RF radiation, or magnetic field | Complies with IEC 60601-1:2005 Medical Device Specification Requirements |
Adjustable Sensitivity and Audio Alarm Levels | Medical Power Supply: 100 to 240 VAC, 47 to 63 Hz, 42 Watts |
Conforms to Applicable Recommendations and Standards including FDA, ACR, AAMI, Joint Commission, FGI and VA | Audio Alarm: In portal, adjustable volume |
18 Detection Zones for ACCURATE and FAST locating of a ferromagnetic threat | Photoelectric Sensors: Activates Audio Alarm only when portal threshold is crossed by a ferromagnetic threat, and only on objects entering the MRI room; not on exiting |
Comprehensive Self-Test Function for hospital periodic maintenance, as well as piece of mind | |
Selectable Chime to alert staff of MRI entrance ingress | |
FerrAlert™ Approved Patient Transport Equipment will not trigger an alarm |